125v 5a 10a 15a Bimetal Thermostat Temperature Controller Refrigerator Defrost Thermostat
Product Parameter
Product Name | 125v 5a 10a 15a Bimetal Thermostat Temperature Controller Refrigerator Defrost Thermostat |
Use | Temperature control/Overheat protection |
Reset type | Automatic |
Base material | Resist heat resin base |
Electrical Rating | 15A / 125VAC, 10A / 240VAC, 7.5A / 250VAC |
Operating Temperature | -20°C~150°C |
Tolerance | +/-5°C for open action(Optional +/-3 C or less) |
Protection class | IP00 |
Contact material | Double Solid Silver |
Dielectric Strength | AC 1500V for 1 minute or AC 1800V for 1 second |
Insulation Resistance | More than 100MΩ at DC 500V by Mega Ohm tester |
Resistance Between Terminals | Less than 50MΩ |
Diameter of bimetal disc | Φ12.8mm(1/2″) |
Approvals | UL/ TUV/ VDE/ CQC |
Terminal type | Customized |
Cover/Bracket | Customized |
Applications
- Rice Cooker - Dishwasher
- Boiler - Washing Machine
- Water Heater - Oven
- Water Dispenser - Dehumidifier
- Coffee maker - Water purifier
- Fan Heater - Bidet
- Sandwich Toaster
- Other Small Appliances
The Advantage of Automatic Reset Thermostat
Advantage
- The contacts have good repeatability and reliable snap action;
- The contacts are on and off without arcing, and the service life is long;
- Little interference to radio and audio-visual appliances.
- Lightweight but high durability;
- The temperature characteristic is fixed, no adjustment is needed, and -the fixed value is optional;
- High precision of action temperature and accurate temperature control;
Product Advantage
- Automatic reset for convenience
- Compact, but capable of high currents
- Temperature control and overheating protection
- Easy mounting and quick response
- Optional mounting bracket available
- UL and CSA recognized
Feature Advantage
Automatic reset temperature control switch: as the temperature increases or decreases, the internal contacts are automatically opened and closed.
Manual reset temperature control switch: When the temperature rises, the contact will automatically open; when the temperature of the controller cools down, the contact must be reset and closed again by manually pressing the button.
Craft Advantage
One-time action:
Automatic and manual integration.
Testing Process
Test method for action temperature: install the product on the test board, put it in the incubator, first set the temperature at 10°C, when the temperature of the incubator reaches 10°C, keep it for 3 minutes, and then cool down by 1°C every 2 minutes, testing the recovery temperature of the product. At this time, the current through the terminal is below 100mA. When the product is turned on, set the temperature of the incubator at 6 ° C. When the temperature of the incubator reaches 6 ° C, keep it for 3 minutes, and then increase the temperature by 1°C every 2 minutes to test the disconnection temperature of the product.
Our product has passed the CQC,UL,TUV certification and so on, has applied for patents accumulatively more than 32 projects and has obtained scientific research departments above the provincial and ministerial level more than 10 projects. Our company has also passed the ISO9001 and ISO14001 system certificated, and national intellectual property system certificated.
Our research and development and production capacity of the company’s mechanical and electronic temperature controllers have ranked in the forefront of the same industry in the country.